Browsing by Author "Haberl, J. S."
Now showing items 1-20 of 236
-
Haberl, J. S.; Culp, C.; Yazdani, B. (Energy Systems Laboratory, 2007-08)In the pages that follow, 15% above-code measures for new commercial buildings are presented for the 41 non-attainment and affected counties in Texas, separated by climate area. Each page contains a description of the ...
-
Haberl, J. S.; Culp, C.; Yazdani, B. (Energy Systems Laboratory (http://esl.tamu.edu), 2007-08)In the pages that follow, 15% above-code measures for new residential buildings are presented for the 41 non-attainment and affected counties in Texas, separated by climate area. Each page contains a description of the ...
-
Sweeney, J., Jr.; Lockhart, D.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)The Energy and Environmental Data System (EEDS) is a web application that facilitates web-based viewing of the Energy Systems Lab's extensive building energy databases. EEDS is the initial framework for a growing set of ...
-
Haberl, J. S.; Bou-Saada, T. E.; Saman, N. F. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)This report contains engineering calculations for seven (7) air-side, heating, ventilating and air conditioning systems (HVAC) systems, including: dual duct constant volume (DDCAV), dual duct variable volume (DDVAV), ...
-
Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2001)This report contains engineering calculations for four (4) air-side, heating, ventilating and air-conditioning systems (HVAC) systems, including: dual duct constant volume (DDCAV), dual duct variable volume (DDVAV), constant ...
-
Im, P.; Haberl, J. S.; Culp, C.; Yazdani, B. (2008-07-18)In August 2004, the Environmental Protection Agency (EPA) issued guidance on quantifying the air emissions benefits from electric sector energy efficiency and renewable energy. Because there was no clear best strategy, ...
-
Bou-Saada, T. E.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1993)The Child Development Center (CDC) was designed to be a "showpiece" model building. Its construction included energy efficient features, including a photovoltaic system, solar hot water system, energy efficient lighting, ...
-
Bou-Saada, T. E.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University; Department of Mechanical Engineering, Texas A&M University, 1994)The U.S.D.O.E. Forrestal Child Development Center (CDC) was designed to be a "showpiece" model building. Its construction included energy efficient features such as efficient lighting, a photovoltaic system, an energy ...
-
Christman, K. D.; Haberl, J. S.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu), 2009-11)This analysis was conducted to identify the energy cost savings from retrofitting Texas buildings with air-to-air ERV (Energy Recovery Ventilator) systems. This analysis applied ERV and psychrometric equations in a bin-type ...
-
Malhotra, M.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2006)
-
Chen, L.; Kissock, J. K.; Haberl, J. S.; Heneghan, T.; Ruch, D.; O'Neal, D. L.; Katipamula, S.; Hinchey, S.; Wang, J.; Claridge, D. E. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 1990)The analysis effort during the first year of the Texas LoanSTAR Monitoring and Analysis Program has emphasized selection and development of baseline analysis techniques to cover the range of buildings expected in the ...
-
Sylvester, K. E.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2000)Energy efficient glazing is necessary to reduce heat gains or losses that contribute to the high-energy use of buildings. However, high-rise commercial buildings that use energy efficient glazing are still consumptive. To ...
-
Haberl, J. S.; Yazdani, B.; Baltazar, J. C.; Parker, P.; Ellis, S.; Mukhopadhyay, J.; Kim, H.; Gilman, D.; Degelman, L.; Zilbertshtien, G.; Clardige, D. (Energy Systems Laboratory, 2013-10)
-
Kim, S.; Haberl, J. S. (Energy Systems Laboratory, 2008-06)This report describes the application and verification of duct model on DOE 2.1e version 119 using ASHRAE 152-2004 (Method of Test for Determining the Design and Seasonal Efficiencies of Residential Thermal Distribution ...
-
Haberl, J. S.; Claridge, D. E.; Culp, C. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2005)
-
Haberl, J. S.; Reeves, G.; Gillespie, K.; Claridge, D. E.; Cowan, J.; Culp, C.; Frazell, W.; Heinemeier, K.; Kromer, S.; Kummer, J.; Mazzucchi, R.; Reddy, A.; Schiller, S.; Sud, I.; Wolpert, J.; Wutka, T. (Energy Systems Laboratory (http://esl.tamu.edu); Texas A&M University (http://www.tamu.edu), 2001)ASHRAE has recently completed the development of Guideline 14 to fill a need for a standard set of energy (and demand) savings calculation procedures. Guideline 14 is intended to be a guideline that provides a minimum ...
-
Sweeney, J., Jr.; Haberl, J. S. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2002)The Automated Data Quality process development is an effort to automate the analysis and monitoring of the Energy Systems Lab's (ESL) polling and energy data process. Polling status refers to basic telecommunication line ...
-
Haberl, J. S.; Baltazar, J. C.; Sung, Y. H.; Claridge, D. E.; Turner, W. D. (2002-12)This report presents electricity, natural gas and cooling baselines for the thermal plant, buildings located in the 87000 block, and the III Corp building at Ft. Hood. A baseline analysis is also presented for the natural ...
-
Haberl, J. S.; Baltazar-Cervantes, J. C.; Liu, Z.; Claridge, D. E.; Turner, W. D. (Energy Systems Laboratory (http://esl.tamu.edu), Texas A&M University, 2003)This report presents electricity, natural gas and cooling baselines for the thermal plant, buildings located in the 87000 block, III Corp building and other buildings that were determined to be part of the ESPC project at ...
-
Haberl, J. S.; Liu, Z. (2007-09-21)This report presents electricity, natural gas and cooling baselines for the Thermal Plant, III Corp building, Darnall Hospital, Main Substation, West Substation, and North Substation. The baselines developed for this ...